公开数据集
数据结构 ? 3.16G
Data Structure ?
* 以上分析是由系统提取分析形成的结果,具体实际数据为准。
README.md
The STAFF III database was acquired during 1995–96 at Charleston Area Medical Center (WV, USA) where single prolonged balloon inflation had been introduced to achieve optimal results of percutaneous transluminal coronary angiography (PTCA) procedures, replacing the typical series of brief inflations. The lead investigator Dr. Stafford Warren designed the study protocol together with Dr. Galen Wagner at Duke University Medical Center (Durham, NC, USA); Dr. Michael Ringborn (Blekinge Hospital, Karlskrona, Sweden) was responsible for data acquisition. The database consists of ECG recordings from 104 patients, accounting for substantial inter-patient variability in reaction to prolonged balloon inflation as well as variability of heart rhythm and waveform morphology. only patients receiving elective PTCA in one of the major coronary arteries were included. Patients suffering from ventricular tachycardia, undergoing an emergency procedure, or demonstrating signal loss during acquisition, were excluded.
Data Collection
The standard procedure was defined as follows. Pre-inflation (baseline) ECGs were acquired for 5 min at rest in supine position in either a relaxing room or the catheterization laboratory, or both, prior to any catheter insertion. Inflation ECGs were acquired up to five times in each patient. The mean inflation time was 4 min 23 s, ranging from 1 min 30 s to 9 min and 54 s. In 86 inflations, the balloon did not go up immediately at the beginning of the recording, but after 4 to 205 s into the recording. Moreover, in some cases, the balloon went down before the recording ended, with a postinflation period >60 s in all but 11 inflations. All time instants related to balloon inflation/deflation were manually annotated. Post-inflation ECGs were acquired for 5 min at rest in supine position in either the catheterization laboratory or the relaxing room, or both.
The database contains a total of 152 occlusions in the major coronary arteries, distributed as 58 occlusions in left anterior descendent (LAD) artery, 59 in right coronary artery (RCA), 32 in left circumflex artery (LCX), and 3 in the left main (LM) artery. based on ECG criteria, 35 patients had previous myocardial infarction.
The database consists of standard 12-lead ECG data. Standard electrode placements were used for the precordial ECG leads, whereas the limb leads were obtained with the Mason–Likar electrode configuration to reduce noise originating from skeletal muscle. Data acquisition was based on custom-made equipment by Siemens–Elema AB (Solna, Sweden) with an extraordinary dynamic input amplitude range. The ECG was digitized at a sampling rate of 1000 Hz and an amplitude resolution of 0.625 µV. These specifications ensured that high-resolution digital signals could be produced which made it possible to analyze high-frequency components as well as other subtle electrophysiological phenomena.
Originally, scntigraphic images were also obtained by injecting Technetium Tc99m Sestamibi for localizing the myocardium supplied by the temporarily occluded artery. However, these images have not come to play any significant role as they are only available for a small number of all patients, and therefore not provided for download on the Physionet website.
Dye injections during catheterization and angiography may case changes of the ECG morphology, and the injections are therefore annotated. However, not all injections were annotated, and therefore users are advised to be cautious when ECG changes are observed that mimic the dynamics commonly observed together with annotated injections.
Data Files
All clinical information and annotations are included in the xlsx and ods format spreadsheets, including columns which describe the measurement type correspond to each recording file. The event times related to the balloon inflation/deflation and the contrast injection are also provided as WFDB annotator files.
Each recording in the database is defined by the data files *.dat and *.hea, together with an annotation file *.event which states times for balloon inflation/deflation and contrast injection (only available for certain recordings).
Comments on the original inflation annotations and the introduction of complementary information
In some files (marked in red in the spreadsheets), we identified additional inflations, not originally indicated in the original spreadsheet. This was done by checking the length of a recording vs the length of inflations; if these two numbers agreed, then we assumed that two or possibly more inflations occurred in the recording. This was the case for the following files: 7c, 11c, 39d, 53c, and 64b (2 inflations in total), and 39c (3 inflations). In addition, three recordings: 29c, 31c, and 77c, were already marked as having two inflations in the original spreadsheet. All of these extrapolated inflations are included in the .event annotation files.
In file 27c (with inflation), the time until inflation was annotated. We then assumed that the remaining part was recorded during inflation. It may be the case that the balloon went down before the end of the recording, but this information is missing.
For the second and the third inflation, if it exists, the annotated time until inflation (D0) is not strictly the time until inflation as D0 also includes the durations of previous pre-inflation(s), inflation(s), and post-inflation(s).
Pablo Laguna, Leif Sörnmo, Juan Pablo Martínez, January 19, 2017.
Contributors
Since its acquisition, the STAFF III Database has been distributed by Prof. Leif Sörnmo (Lund University, Sweden), responsible for the acquisition equipment and software. The use of the STAFF III database has broadened considerably over the years, with importance for several other research problems than high-frequency ECG analysis. Although the original study protocol of the database was designed to address a set of clinical issues, the database has turned out to be highly valuable also for developing, improving, and evaluating a wide range of signal processing techniques. This database has prompted methodological development in many areas related to ischemia, see the review by Laguna and Sörnmo (2014).
The database was prepared for Physionet by:
- Pablo Laguna, Prof., Zaragoza University, Spain (laguna@unizar.es)
- Leif Sörnmo, Prof., Lund University, Sweden (leif.sornmo@bme.lth.se)
- Juan Pablo Martínez, Assoc. Prof., Zaragoza University, Spain (jpmart@unizar.es)
References
The first paper listed below is the study for which the database was acquired. The other two papers review work exploring the STAFF III database, either clinical or methodological.
- Pettersson J, Carro E, Edenbrandt L, Pahlm O, Ringborn M, Sörnmo L, Warren S, Wagner G. "Spatial, individual and temporal variation of the high frequency QRS amplitudes in the 12 standard electrocardiographic leads," Am Heart J, 139(2 Pt 1):352-358, 2000.
- Warren SG, Wagner GS. "The STAFF studies of the first 5 minutes of percutaneous coronary angioplasty balloon occlusion in man". J Electrocardiol 2014;47(4):402–7.
- P. Laguna, L. Sörnmo, "The STAFF III ECG database and its significance in methodological development evaluation", J Electrocardiol, Vol. 47, pp. 408–417, 2014.
When using this resource, please cite the original publication:
Please include the standard citation for PhysioNet: (show more options)
Goldberger, A., Amaral, L., Glass, L., Hausdorff,
J., Ivanov, P. C., Mark, R., ... & Stanley, H. E. (2000).
PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research
resource for complex physiologic signals. Circulation [Online]. 101
(23), pp. e215–e220.
帕依提提提温馨提示
该数据集正在整理中,为您准备了其他渠道,请您使用
- 分享你的想法
全部内容
数据使用声明:
- 1、该数据来自于互联网数据采集或服务商的提供,本平台为用户提供数据集的展示与浏览。
- 2、本平台仅作为数据集的基本信息展示、包括但不限于图像、文本、视频、音频等文件类型。
- 3、数据集基本信息来自数据原地址或数据提供方提供的信息,如数据集描述中有描述差异,请以数据原地址或服务商原地址为准。
- 1、本站中的所有数据集的版权都归属于原数据发布者或数据提供方所有。
- 1、如您需要转载本站数据,请保留原数据地址及相关版权声明。
- 1、如本站中的部分数据涉及侵权展示,请及时联系本站,我们会安排进行数据下线。