公开数据集
数据结构 ? 440M
Data Structure ?
* 以上分析是由系统提取分析形成的结果,具体实际数据为准。
README.md
This database includes 25 long-term ECG recordings of human subjects with atrial fibrillation (mostly paroxysmal).
Data Description
Of these, 23 records include the two ECG signals (in the .dat files); records 00735 and 03665 are represented only by the rhythm (.atr) and unaudited beat (.qrs annotation files.
The individual recordings are each 10 hours in duration, and contain two ECG signals each sampled at 250 samples per second with 12-bit resolution over a range of ±10 millivolts. The original analog recordings were made at Boston's Beth Israel Hospital (now the Beth Israel Deaconess Medical Center) using ambulatory ECG recorders with a typical recording bandwidth of approximately 0.1 Hz to 40 Hz. The rhythm annotation files (with the suffix .atr) were prepared manually; these contain rhythm annotations of types (AFIB (atrial fibrillation), (AFL (atrial flutter), (J (AV junctional rhythm), and (N (used to indicate all other rhythms). (The original rhythm annotation files, still available in the old directory, used AF, AFL, J, and N to mark these rhythms; the atr annotations in this directory have been revised for consistency with those used for the MIT-BIH Arrhythmia Database.) Beat annotation files (with the suffix .qrs) were prepared using an automated detector and have not been corrected manually. For some records, manually corrected beat annotation files (with the suffix .qrsc) are available. (The .qrs annotations may be useful for studies of methods for automated AF detection, where such methods must be robust with respect to typical QRS detection errors. The .qrsc annotations may be preferred for basic studies of AF itself, where QRS detection errors would be confounding.) Note that in both .qrs and .qrsc files, no distinction is made among beat types (all beats are labelled as if normal).
Release Info
Until November 2000, only one of the signal files (for record 04936) was available. The original 9-track tapes from 1983 for these records have now been read to produce the other signal files in this directory. In a few cases (04043, 08405, and 08434) isolated data blocks from the original tapes were unreadable. In these cases, the missing data, corresponding to 10.24 seconds for each missing block, have been replaced with a flat segment of samples with amplitudes of zero. See notes.txt for details.
In March 2014, Henian Xia reported that the .qrs annotations were not aligned with the ECG waveforms in record 07859, and investigation showed that 2569 samples appeared to be missing from the beginning of the record. The original annotation file has been renamed 07859.qrs-, and a realigned version of it (without its initial 14 annotations) is available as 07859.qrs. A correctly aligned, manually reviewed annotation file was also produced at that time, and is now available here as 07859.qrsc.
帕依提提提温馨提示
该数据集正在整理中,为您准备了其他渠道,请您使用
- 分享你的想法
全部内容
数据使用声明:
- 1、该数据来自于互联网数据采集或服务商的提供,本平台为用户提供数据集的展示与浏览。
- 2、本平台仅作为数据集的基本信息展示、包括但不限于图像、文本、视频、音频等文件类型。
- 3、数据集基本信息来自数据原地址或数据提供方提供的信息,如数据集描述中有描述差异,请以数据原地址或服务商原地址为准。
- 1、本站中的所有数据集的版权都归属于原数据发布者或数据提供方所有。
- 1、如您需要转载本站数据,请保留原数据地址及相关版权声明。
- 1、如本站中的部分数据涉及侵权展示,请及时联系本站,我们会安排进行数据下线。