Data Set Information:
A chemical detection platform composed of 8 chemo-resistive gas sensors was exposed to turbulent gas mixtures generated naturally in a wind tunnel. The acquired time series of the sensors are provided.
The experimental setup was designed to test gas sensors in realistic environments. Traditionally, chemical detection systems based on chemo-resistive sensors include a gas chamber to control the sample air flow and minimize turbulence. Instead, we utilized a wind tunnel with two independent gas sources that generate two gas plumes. The plumes get naturally mixed along a turbulent flow and reproduce the gas concentration fluctuations observed in natural environments. Hence, the gas sensors can capture the spatio-temporal information contained in the gas plumes.
a) Chemical detection platform:
The chemical detection platform was composed of 8 MOX gas sensors that generate a time-dependent multivariate response to the different gas stimuli. The utilized sensors were made commercially available by Figaro (TGS2611, TGS2612, TGS2610, TGS2600, TGS2602 TGS2620). The operating temperature of the sensors was controlled by the built-in heater, which was kept at a constant voltage of 5V. The detection platform also includes Temperature and Relative Humidity sensors. The generated sensors' responses were acquired at a sampling rate of 20 ms for the whole duration of the experiment.
b) Wind tunnel:
In order to generate two independent gas plumes in an open environment, we built a 2.5 m x 1.2 m x 0.4 m wind tunnel facility with two gas sources (labeled as source1 and source2). Each source was controlled independently to release the selected volatiles at different flow rates, which generated different concentration levels in the sensors' position. The wind generator created a turbulent flow that constantly displaced the introduced volatiles towards the exhaust outlet.
c) Experimental protocol:
We exposed the detection unit to mixtures of Ethylene with Methane or Carbon Monoxide. The mixtures were originated releasing Ethylene at source1 and releasing Methane / Carbon Monoxide at source2.
Each volatile was released at four different flows (zero z, low l, medium m, and high h), providing up to 30 different mixture configurations: 15 mixtures of Ethylene with CO (h+h, h+m, h+l, a€|, z+h, z+m, z+l) and 15 mixtures of Ethylene with Methane. Each configuration was repeated 6 times. Hence, the complete dataset was composed of 180 measurements, which were performed in a random order.
By means of a GCMS system, the mean concentration levels at the sensors' location were estimated: Ethylene (l: 31 ppm, m: 46 ppm, h: 96 ppm), CO (l: 270 ppm, m: 397 ppm, h: 460 ppm), Methane (l: 51 ppm, m: 115 ppm, h: 131 ppm). It is worth noting that GC-MS systems only provide the mean value of the concentration and are not sensitive to concentration fluctuations.
Each measurement, which had a total duration of 300 seconds, was performed as follows: Initially no gas was released and clean air flowed along the wind tunnel. 60 seconds after, both sources started to release the corresponding volatile at the specified flow rate. The duration of the gas release was 180 s. Finally, the system acquired the recovery to the baseline for another 60 s.
Attribute Information:
The dataset is presented in 180 text files, where each file corresponds to a different measurement. The filenames identify the measurements as follows: The first 3 characters of the filename are a local identifier, which is not related to the order of the measurements; characters 5-8 indicate the concentration level of Ethylene released at source2 (n: zero, L: Low, M: Medium, H: High); the last 4 characters indicate the gas released at source1 (Me: Methane, CO: Carbon Monoxide) and the concentration level.
For example, file 007_Et_L_Me_H contains time series acquired when Ethylene was released at Low concentration (31 ppm, mean concentration) and Methane at High concentration (131 ppm, mean concentration).
Each file includes the acquired time series, presented in 11 columns: Time (s), Temperature (oC), Relative Humidity (%), and the readings of the 8 gas sensors: TGS2600, TGS2602, TGS2602, TGS2620, TGS2612, TGS2620, TGS2611, TGS2610. The readings can be converted to sensor resistance by Rs(KOhm)=10*(3110-A)/A, where A is the acquired value.
The raw acquired time series are provided, and also time series down sampled at 100 ms.
Relevant Papers:
The description of the experimental setup and chemical detection platform can be found in [1].
The wind tunnel was adapted from a previous setup to include two independent gas sources. See [2] for additional details on the experimental setup.
[1]: Jordi Fonollosa, Irene Rodr?-guez-Lujan, Marco Trincavelli, Alexander Vergara and Ramon Huerta
Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry. Sensors 2014.
[2]: Vergara, Alexander, Jordi Fonollosa, Jonas Mahiques, Marco Trincavelli, Nikolai Rulkov, and Ramon Huerta. 'On the performance of gas sensor arrays in open sampling systems using Inhibitory Support Vector Machines.' Sensors and Actuators B: Chemical 185 (2013): 462-477.
Citation Request:
The following citation is requested if you use the dataset:
Jordi Fonollosa, Irene Rodriguez-Lujan, Marco Trincavelli, Alexander Vergara and Ramon Huerta
Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry. Sensors 2014.
Creators:
Jordi Fonollosa (fonollosa '@'ucsd.edu)
BioCircutis Institute
University of California San Diego
San Diego, California, USA
Donors of the Dataset:
Jordi Fonollosa (fonollosa '@'ucsd.edu)
Irene Rodriguez-Lujan (irrodriguezlujan '@' ucsd.edu)
Marco Trincavelli (marco.trincavelli '@' oru.se)
Alexander Vergara
Ramon Huerta (rhuerta '@' ucsd.edu)
帕依提提提温馨提示
该数据集正在整理中,为您准备了其他渠道,请您使用
- 分享你的想法
全部内容
数据使用声明:
- 1、该数据来自于互联网数据采集或服务商的提供,本平台为用户提供数据集的展示与浏览。
- 2、本平台仅作为数据集的基本信息展示、包括但不限于图像、文本、视频、音频等文件类型。
- 3、数据集基本信息来自数据原地址或数据提供方提供的信息,如数据集描述中有描述差异,请以数据原地址或服务商原地址为准。
- 1、本站中的所有数据集的版权都归属于原数据发布者或数据提供方所有。
- 1、如您需要转载本站数据,请保留原数据地址及相关版权声明。
- 1、如本站中的部分数据涉及侵权展示,请及时联系本站,我们会安排进行数据下线。